Multipositionsventile LOW PRESSURE

Dead-end flowpath - SD configuration

SD valves select one of 4 to 16 dead-ended streams. The selected stream flows from the outlet to a sample valve, pressure sensor, detector, column, etc. The same flowpath can also be used to direct one
stream to a number of outlets in applications such as fraction collection.
  1/16" fittings, 0.75 mm ports (.030")   MWType Includes 2" standoff. Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU.
Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply)
400 psi gas; 200°C max
Nitronic 60 valve body Valcon E rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  6 Position 10 Position 12 Position 16 Position
  Artikelnummer   Artikelnummer   Artikelnummer   Artikelnummer  
Manual (not recommendet) 2CSD6MWE   2CSD10MWE   2CSD12MWE   2CSD16MWE  
With air actuator A2CSD6MWE   A2CSD10MWE   A2CSD12MWE   A2CSD16MWE  
With standard electric actuator E2CSD6MWE   E2CSD10MWE   E2CSD12MWE   E2CSD16MWE  
With microelectric actuator EMT2CSD6MWE   EMT2CSD10MWE   EMT2CSD12MWE   EMT2CSD16MWE  
Replacement valve DCSD6MWE   DCSD10MWE   DCSD12MWE   DCSD16MWE  
1/8" fittings, 1.0 mm ports (.040")   MWType
4 - 8 Positions: 400 psi gas; 200°C max 10 - 16 Positions: 200 psi gas; 200°C max Nitronic 60 valve body, Valcon E rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium
Includes 2" standoff. Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU.
Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply)
  6 Position 10 Position 12 Position 16 Position
  Artikelnummer   Artikelnummer   Artikelnummer   Artikelnummer  
Manual (not recommendet) 2SD6MWE   2SD10MWE   2SD12MWE   2SD16MWE  
With air actuator A2SD6MWE   A2SD10MWE   A2SD12MWE   A2SD16MWE  
With standard electric actuator E2SD6MWE   E2SD10MWE   E2SD12MWE   E2SD16MWE  
With microelectric actuator EMT2SD6MWE   EMT2SD10MWE   EMT2SD12MWE   EMT2SD16MWE  
Replacement valve DSD6MWE   DSD10MWE   DSD12MWE   DSD16MWE  
Replacement rotor SSASD6MWE   SSASD10MWE   SSASD12MWE   SSASD16MWE  
  1/4" fittings, 4.0 mm ports (.156")   MWType Includes 2" standoff. Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU.
Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply)
100 psi gas; 75°C max
Nitronic 60 valve body Valcon E2 rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  4 Position 6 Position 8 Position 10 Position
  Artikelnummer   Artikelnummer   Artikelnummer   Artikelnummer  
With air actuator AH2VLSD4MWE2   AH2VLSD6MWE2   AH2VLSD8MWE2   AH2VLSD10MWE2  
With standard electric actuator E2VLSD4MWE2   E2VLSD6MWE2   E2VLSD8MWE2   E2VLSD10MWE2  
With microelectric actuator EMT2VLSD4MWE2   EMT2VLSD6MWE2   EMT2VLSD8MWE2   EMT2VLSD10MWE2  
Replacement valve DVLSD4MWE2   DVLSD6MWE2   DVLSD8MWE2   DVLSD10MWE2  
Replacement valve SSAVLSD4MWE2   SSAVLSD6MWE2   SSAVLSD8MWE2   SSAVLSD10MWE2  
 

Common outlet flowpath - SC configuration

SC valves are similar to the SD configuration, except that instead of being dead-ended the non-selected streams flow to a common outlet.
  1/16" fittings, 1.0 mm ports (.040")   MW Type
Includes 2" standoff. Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU. 200 psi gas   Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply).
200 psi gas; 200°C max
Nitronic 60 valve body Valcon E rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  6 Position 10 Position 12 Position 16 Position
  Artikelnummer   Artikelnummer   Artikelnummer   Artikelnummer  
Manual (not recommendet) 2CSC6MWE   2CSC10MWE   2CSC12MWE   2CSC16MWE  
With air actuator     A2CSC10MWE   A2CSC12MWE   A2CSC16MWE  
With standard electric actuator E2CSC6MWE   E2CSC10MWE   E2CSC12MWE   E2CSC16MWE  
With microelectric actuator EMT2CSC6MWE   EMT2CSC10MWE   EMT2CSC12MWE   EMT2CSC16MWE  
Replacement valve DCSC6MWE   DCSC10MWE   DCSC12MWE   DCSC16MWE  
Replacement valve SSACSC6MWE   SSACSC10MWE   SSACSC12MWE   SSACSC16MWE  
1/8" fittings, 1.0 mm ports (.040")   MW Type
Includes 2" standoff. Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU. 200 psi gas   Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply).
200 psi gas; 200°C max Nitronic 60 valve body, Valcon E rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  6 Position 10 Position 12 Position 16 Position
  Artikelnummer   Artikelnummer   Artikelnummer   Artikelnummer  
Manual (not recommendet) 2SC6MWE   2SC10MWE   2SC12MWE   2SC16MWE  
With air actuator     A2SC10MWE   A2SC12MWE   A2SC16MWE  
With standard electric actuator E2SC6MWE   E2SC10MWE   E2SC12MWE   E2SC16MWE  
With microelectric actuator EMT2SC6MWE   EMT2SC10MWE   EMT2SC12MWE   EMT2SC16MWE  
Replacement valve DSC6MWE   DSC10MWE   DSC12MWE   DSC16MWE  
Replacement valve SSASC6MWE   SSASC10MWE   SSASC12MWE   SSASC16MWE  
  1/4" fittings, 4.0 mm ports (.156")   MW Type
Includes 2" standoff. Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU. 200 psi gas   Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply).
100 psi gas; 75°C max
Nitronic 60 valve body Valcon E2 rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  4 Position 6 Position 8 Position
  Artikelnummer   Artikelnummer   Artikelnummer  
With air actuator AH2VLSC4MWE2   AH2VLSC6MWE2   AH2VLSC8MWE2  
With standard electric actuator E2VLSC4MWE2   E2VLSC6MWE2   E2VLSC8MWE2  
With microelectric actuator EMT2VLSC4MWE2   EMT2VLSC6MWE2   EMT2VLSC8MWE2  
Replacement valve DVLSC4MWE2   DVLSC6MWE2   DVLSC8MWE2  
Replacement valve SSAVLSC4MWE2   SSAVLSC6MWE2   SSAVLSC8MWE2  
  Flow-through flowpath - SF configuration
SD and SC valves select and isolate one of 4 to 16 streams, with the remainder dead-ended in the SD and flowing to a common outlet in the SC. The SF is similar, but carries the evolution a step further with the non-selected streams flowing through individual outlets.
  1/16" fittings, 1.0 mm ports (.040")
Includes 2" standoff. Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU. Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply)
200 psi gas; 200°C max
Nitronic 60 valve body Valcon E rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  6 Position 10 Position 12 Position 16 Position
  Artikelnummer   Artikelnummer   Artikelnummer   Artikelnummer  
Manual (not recommendet) 2CSF6MWE   2CSF10MWE   2CSF12MWE   2CSF16MWE  
With air actuator     A2CSF10MWE   A2CSF12MWE   A2CSF16MWE  
With standard electric actuator E2CSF6MWE   E2CSF10MWE   E2CSF12MWE   E2CSF16MWE  
With microelectric actuator EMT2CSF6MWE   EMT2CSF10MWE   EMT2CSF12MWE   EMT2CSF16MWE  
Replacement valve DCSF6MWE   DCSF10MWE   DCSF12MWE   DCSF16MWE  
Replacement valve SSACSF6MWE   SSACSF10MWE   SSACSF12MWE   SSACSF16MWE  
  1/8" fittings, 1.0 mm ports (.040")   MW Type
Includes 2" standoff. Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU. 200 psi gas. Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply)
200 psi gas; 200°C max Nitronic 60 valve body, Valcon E rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  6 Position 10 Position 12 Position 16 Position
  Artikelnummer   Artikelnummer   Artikelnummer   Artikelnummer  
Manual (not recommendet) 2SF6MWE   2SF10MWE   2SF12MWE   2SF16MWE  
With air actuator     A2SF10MWE   A2SF12MWE   A2SF16MWE  
With standard electric actuator E2SF6MWE   E2SF10MWE   E2SF12MWE   E2SF16MWE  
With microelectric actuator EMT2SF6MWE   EMT2SF10MWE   EMT2SF12MWE   EMT2SF16MWE  
Replacement valve DSF6MWE   DSF10MWE   DSF12MWE   DSF16MWE  
Replacement valve SSASF6MWE   SSASF10MWE   SSASF12MWE   SSASF16MWE  
1/4" fittings, 4.0 mm ports (.156")   MWType
Includes 2" standoff. Ask about closemount assembly if valve will not be heated. Manual version is not available.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU.
Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply)
100 psi gas; 75°C max
Nitronic 60 valve body Valcon E2 rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  4 Position 6 Position 8 Position
  Artikelnummer   Artikelnummer   Artikelnummer  
With air actuator AH2VLSF4MWE2   AH2VLSF6MWE2   AH2VLSF8MWE2  
With standard electric actuator E2VLSF4MWE2   E2VLSF6MWE2   E2VLSF8MWE2  
With microelectric actuator EMT2VLSF4MWE2   EMT2VLSF6MWE2   EMT2VLSF8MWE2  
Replacement valve DVLSF4MWE2   DVLSF6MWE2   DVLSF8MWE2  
Replacement valve SSAVLSF4MWE2   SSAVLSF6MWE2   SSAVLSF8MWE2  
Trapping flowpath - ST configuration
ST valves are used for multi-column, multi-sample, or multi-trap operations, and are available for use with 4 to 16 loops, or positions.
1/16" fittings, 0.75 mm ports (.030")   MWType
Includes 2" standoff. Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU.
Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply)
200 psi gas; 200°C max
Nitronic 60 valve body Valcon E rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  6 Position 10 Position 12 Position 16 Position
  Artikelnummer   Artikelnummer   Artikelnummer   Artikelnummer  
Manual (not recommendet) 2CST6MWE   2CST10MWE   2CST12MWE   2CST16MWE  
With air actuator A2CST6MWE   A2CST10MWE   A2CST12MWE   A2CST16MWE  
With standard electric actuator E2CST6MWE   E2CST10MWE   E2CST12MWE   E2CST16MWE  
With microelectric actuator EMT2CST6MWE   EMT2CST10MWE   EMT2CST12MWE   EMT2CST16MWE  
Replacement valve DCST6MWE   DCST10MWE   DCST12MWE   DCST16MWE  
Replacement valve SSACST6MWE   SSACST10MWE   SSACST12MWE   SSACST16MWE  
1/16" Stainless steel loops   for MW Type valves
Each stainless steel loop includes two stainless nuts and two stainless ferrules. Order special fittings separately. When a set of loops is ordered, loops will be supplied from the same lot.
Volume Artikelnummer
50 µl SL50CSTP
100 µl SL100CSTP
250 µl SL250CSTP
500 µl SL500CSTP
1 ml SL1KCSTP
2 ml SL2KCSTP
5 ml SL5KCSTP
10 ml SL10KCSTP
1/8" fittings, 1.0 mm ports (.040")   MW Type
Includes 2" standoff Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU. 200 psi gas   Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply).
200 psi gas; 200°C max Nitronic 60 valve body, Valcon E rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  6 Position 10 Position 12 Position 16 Position
  Artikelnummer   Artikelnummer   Artikelnummer   Artikelnummer  
Manual (not recommendet) 2ST6MWE   2ST10MWE   2ST12MWE   2ST16MWE  
With air actuator     A2ST10MWE   A2ST12MWE   A2ST16MWE  
With standard electric actuator E2ST6MWE   E2ST10MWE   E2ST12MWE   E2ST16MWE  
With microelectric actuator EMT2ST6MWE   EMT2ST10MWE   EMT2ST12MWE   EMT2ST16MWE  
Replacement valve DST6MWE   DST10MWE   DST12MWE   DST16MWE  
Replacement valve SSAST6MWE   SSAST10MWE   SSAST12MWE   SSAST16MWE  
  1/8" Stainless steel loops   for MW Type valves
Each stainless steel loop includes two stainless nuts and two stainless ferrules. Order special fittings separately. When a set of loops is ordered, loops will be supplied from the same lot.
Volume Artikelnummer
100 µl SL100STP
250 µl SL250STP
500 µl SL500STP
1 ml SL1KSTP
2 ml SL2KSTP
5 ml SL5KSTP
10 ml SL10KSTP
Trapping/flow-through flowpath - STF configuration
The STF valve is a variation of the ST flowpath, with the single difference that the non-selected streams are returned to their own vents or sources rather than being dead-ended or trapped as they are in the standard ST configuration.
1/16" fittings, 0.75 mm ports (.030")   MW Type
Includes 2" standoff. Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU. 200 psi gas   Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply)
200 psi gas; 200°C max Nitronic 60 valve body, Valcon E rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  6 Position 10 Position 12 Position 16 Position
  Artikelnummer   Artikelnummer   Artikelnummer   Artikelnummer  
Manual (not recommendet) 2CSTF6MWE   2CSTF10MWE   2CSTF12MWE   2CSTF16MWE  
With air actuator     A2CSTF10MWE   A2CSTF12MWE   A2CSTF16MWE  
With standard electric actuator E2CSTF6MWE   E2CSTF10MWE   E2CSTF12MWE   E2CSTF16MWE  
With microelectric actuator EMT2CSTF6MWE   EMT2CSTF10MWE   EMT2CSTF12MWE   EMT2CSTF16MWE  
Replacement valve DCSTF6MWE   DCSTF10MWE   DCSTF12MWE   DCSTF16MWE  
Replacement valve SSACSTF6MWE   SSACSTF10MWE   SSACSTF12MWE   SSACSTF16MWE  
1/8" fittings, 1.0 mm ports (.040")   MW Type
Includes 2" standoff. Ask about closemount assembly if valve will not be heated.
Standard electric actuators: 110 VAC, (230 VAC optional. Consult factory for further details.) Non-CE, restricted use within the EU. 200 psi gas   Microelectric actuators: 24 VDC (includes a 110/230 VAC to 24 VDC power supply)
200 psi gas; 200°C max
Nitronic 60 valve body Valcon E rotor Materials: HastelloyC, Inconel 600, Monel 400, Nickel 200, Nitronic 50,Titanium, Zirconium

  6 Position 10 Position 12 Position 16 Position
  Artikelnummer   Artikelnummer   Artikelnummer   Artikelnummer  
Manual (not recommendet) 2STF6MWE   2STF10MWE   2STF12MWE   2STF16MWE  
With air actuator     A2STF10MWE   A2STF12MWE   A2STF16MWE  
With standard electric actuator E2STF6MWE   E2STF10MWE   E2STF12MWE   E2STF16MWE  
With microelectric actuator EMT2STF6MWE   EMT2STF10MWE   EMT2STF12MWE   EMT2STF16MWE  
Replacement valve DSTF6MWE   DSTF10MWE   DSTF12MWE   DSTF16MWE  
Replacement valve SSASTF6MWE   SSASTF10MWE   SSASTF12MWE   SSASTF16MWE